Simple Modbus Poll user Instructions to read Slave ID 48, on COM 10, Engineering Flow, Register 106:
![modbus poll troubleshooting modbus poll troubleshooting](https://www.controlglobal.com/assets/Uploads/1812-Feat3-Fig1-650-compressor.png)
Modbus poll troubleshooting for free#
Modbus Poll Website Link for Free Download for 30 days ModBus Poll configuration examples It carries a free 30 day trial period to allow usert to debug Modbus enabled installations This program is one of the more commonly utilized debugging tools for folks who use Modbus.
Modbus poll troubleshooting serial#
To READ the Mass Flow Units, Command 20, you will issue 21 in the Parallax Serial Terminal. The complete list of Command Registers is shown below:ĮVEN numbers are WRITES and ODD numbers are READS. Notice the #20 corresponds to the same as Command 20 above. Below is an example of the registers, or commands, for each variable stored in a typical Tactical Flow Meter. If you wish to view EVERY CONFIGURATION Register in your meter, and save it for study, then issue 94,99 and hit enter. If you DO mess up your meter you can always RECOVER the Factory Values as shown here at 12:48 on the time line. Just make sure to never type an EVEN number in any Serial Terminal. In any serial terminal you do NOT get to edit what you enter, there is no backspace recognized. If you accidently issue 20 or some EVEN number, justchange the 20 to 201. As such, to read the value of the registers you ADD ONE to the command set below.įor example, Mass Flow Units is Command 20 in ModBus but for the ASCII Serial Port the command to READ the Mass Flow Units is 21. You will be communicating using an ASCII protocol to provide for simple verification and configuration using a Serial Terminal. VERY IMPORTANT NOTE for using the ANY Serial Terminal: Your Serial Terminal dashboard should look like this: Then click Enable and to test your connection type 43 to view the revision of the meter. Start the Parallax-Serial-Terminal and configure it like THIS if your COM is COM3: To CONFIRM which COM port your Tactical Flow Meter is using simply unplug and plug the USB cable and you will see that Windows re-enumerates the serial ports and the one you see appear and dissappear is the COM for the Tactical Flow Meter. Then, click the Device Manager that shows up above: You may wish to invoke the Windows Device Manager to find which COM port Windows has assigned, or enumerated, to the Tactical Flow Meter by typing Device Manager in WIndows Start Icon as shown below: Once the Parallax Serial Terminal is running select the COM port for the Tactical Flow Meter. We suggest putting it here: C:\TacticalFlow Once downloaded, unzip the file (NOTE… You must UNZIP and NOT run the executable from the Windows UNZIP viewer function) and put the Parallax-Serial-Terminal executable in an easy to find location. The Image from Parallax download site is below: There is a SINGLE Executable so there is no messing with your Registry!
Modbus poll troubleshooting install#
Right click and download and install on your PC. You will be directed to the page that looks like the image below. This program is a very simple, and small footprint, Serial Terminal to communicate to the Tactical Flow Meter using the USB port. Serial Terminal:ĭownload Link for Serial Terminal. This program is specifically designed for the Tactical Flow Meter.
Modbus poll troubleshooting how to#
Watch Video below to see how to use the program. The Tactical Flow Meter has constants in the form of an I32 Integer, a IEEE 754 Single Float from 4 bytes and a string. It is very simple and is only provided as a test tool to assist you in using the ModBus protocol and learning how to parse out the data.
Modbus poll troubleshooting pro#
You may wish to skip getting ModBus Pro in favor of using the simnple program shown above. These registers are from one single sample and are for reference. The suppression is handy for suppressing low value totalizing events and low end control system anomalies. Note: Zero Suppression provides the user with the ability to suppress readings from the flow meter, however we will not suppress the Sensor RAW value from your being able to read it.
![modbus poll troubleshooting modbus poll troubleshooting](https://forums.temcocontrols.com/uploads/default/original/2X/d/d4e0831c6e3541501d5bd2c62c2da0b99580907d.png)
Termination Character: NONE ModBus Register List: Factory Tactical Flow Meter ModBus COM Setup: These are used in emulation modes for various manufacturers. We also provide some variables in the CDAB Float that are in the IEEE 752 format. To parse the reading from the flow meter the user need only divide the returned Long CDAB value by 10,000. These CDAB Longs carry a 10,000 multiplier to provide FOUR digits of precision. To enjoy the highest level of resolution many values are transmitted as CDAB Longs, that by default, according to the ModBus RTU protocol. The Tactical Flow Meter uses the Modbus RTU Communication protocol. Revision Date: Update: to add Youtube Embed code and functional links. Tactical Flow Meter ModBus and USB Serial Terminal Command Instructions for Thermal Flow Meters.